US: WZDx - Secure Internet (ITS)

Description

This solution is used within the U.S.. It combines standards associated with US: WZDx with those for I–I: Secure Internet (ITS). The US: WZDx standards include upper–layer standards required to implement work zone information data exchanges. The I–I: Secure Internet (ITS) standards include lower–layer standards that support secure communications between ITS equipment using X.509 or IEEE 1609.2 security certificates.

Includes Standards

LevelDocNumFullNameDescription
MgmtIETF RFC 3411An Architecture for Describing Simple Network Management Protocol (SNMP) Management FrameworksThis standard (RFC) defines the basic architecture for SNMPv3 and includes the definition of information objects for managing the SNMP entity's architecture.
MgmtIETF RFC 3412Message Processing and Dispatching for the Simple Network Management Protocol (SNMP)This standard (RFC) contains a MIB that assists in managing the message processing and dispatching subsystem of an SNMP entity.
MgmtIETF RFC 3413Simple Network Management Protocol (SNMP) ApplicationsThis standard (RFC) includes MIBs that allow for the configuration and management of remote Targets, Notifications, and Proxys.
MgmtIETF RFC 3414User–based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)This standard (RFC) contains a MIB that assists in configuring and managing the user–based security model.
MgmtIETF RFC 3415View–based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)This standard (RFC) contains a MIB that supports the configuration and management of the View–based access control model of SNMP.
MgmtIETF RFC 3416Version 2 of the Protocol Operations for the Simple Network Management Protocol (SNMP)This standard (RFC) defines the message structure and protocol operations used by SNMPv3.
MgmtIETF RFC 3418Management Information Base (MIB) for the Simple Network Management Protocol (SNMP)This standard (RFC) defines the MIB to configure and manage an SNMP entity.
MgmtIETF RFC 4293Management Information Base for the Internet Protocol (IP)This standard (RFC) defines the MIB that manages an IP entity.
SecurityIETF RFC 5280Internet X.509 Public Key Infrastructure Certificate and Certificate Revocation List (CRL) ProfileThis standard (RFC) defines how to use X.509 certificates for secure communications over the Internet.
SecurityIETF RFC 8446The Transport Layer Security (TLS) ProtocolThis standard (RFC) specifies Version 1.3 of the Transport Layer Security (TLS) protocol. The TLS protocol provides communications security over the Internet. The protocol allows client/server applications to communicate in a way that is designed to prevent eavesdropping, tampering, or message forgery.
ITS Application EntityWZDxWork Zone Data ExchangeThis standard defines a common format for exchanging work zone information.
FacilitiesIETF RFC 7159The JavaScript Object Notation (JSON) Data Interchange FormatThe JavaScript Object Notation (JSON), a lightweight, text–based, language–independent data interchange format. It was derived from the ECMAScript Programming Language Standard. JSON defines a small set of formatting rules for the portable representation of structured data. This document removes inconsistencies with other specifications of JSON, repairs specification errors, and offers experience–based interoperability guidance.
FacilitiesIETF RFC 7230Hypertext Transfer Protocol (HTTP/1.1): Message Syntax and RoutingThis standard (RFC) defines the main Application Layer protocol used for the world–wide web.
TransNetIETF RFC 2460Internet Protocol, Version 6 (IPv6) SpecificationThis standard (RFC) specifies version 6 of the Internet Protocol (IPv6), also sometimes referred to as IP Next Generation or IPng.
TransNetIETF RFC 4291IP Version 6 Addressing ArchitectureThis standard (RFC) defines the addressing architecture of the IP Version 6 (IPv6) protocol. It includes the IPv6 addressing model, text representations of IPv6 addresses, definition of IPv6 unicast addresses, anycast addresses, and multicast addresses, and an IPv6 node's required addresses.
TransNetIETF RFC 4443Internet Control Message Protocol (ICMPv6) for the Internet Protocol Version 6 (IPv6) SpecificationThis standard (RFC) defines the control messages to manage IPv6.
TransNetIETF RFC 793Transmission Control ProtocolThis standard (RFC) defines the main connection–oriented Transport Layer protocol used on Internet–based networks.
Access Internet Subnet AlternativesA set of alternative standards that includes any Subnet Layer method of connecting to the Internet.

Readiness: High–Moderate

Readiness Description

One significant or possibly a couple minor issues. For existing deployments, the chosen solution likely has identified security or management issues not addressed by the communications solution. Deployers should consider additional security measures, such as communications link and physical security as part of these solutions. They should also review the management issues to see if they are relevant to their deployment and would require mitigation. For new deployments, the deployment efforts should consider a path to addressing these issues as a part of their design activities. The solution does not by itself provide a fully secure implementation without additional work.

Issues

IssueSeverityDescriptionAssociated StandardAssociated Triple
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Moorhead PW Operations Center=>work zone information=>Media
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Fargo PW Operations Center=>work zone information=>Fargo TOC
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)FM Maintenance and Construction Management=>work zone information=>FM Information Service Providers
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)FM Maintenance and Construction Management=>work zone information=>FM Traffic Operations
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)FM Maintenance and Construction Management=>work zone information=>FM Emergency Management
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)FM Maintenance and Construction Management=>work zone information=>Media
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)FM Maintenance and Construction Management=>work zone information=>MATBus
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)West Fargo PW Operations center=>work zone information=>MATBus
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Moorhead PW Operations Center=>work zone information=>MnDOT D4 TOC
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Moorhead PW Operations Center=>work zone information=>RRRDC
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Moorhead PW Operations Center=>work zone information=>MATBus
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Moorhead PW Operations Center=>work zone information=>Fargo TOC
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Fargo PW Operations Center=>work zone information=>MSP DL District
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Fargo PW Operations Center=>work zone information=>MnDOT D4 TOC
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Fargo PW Operations Center=>work zone information=>Media
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Fargo PW Operations Center=>work zone information=>RRRDC
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Fargo PW Operations Center=>work zone information=>NDDOT TOC
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Fargo PW Operations Center=>work zone information=>MATBus
Data not fully defined (medium)MediumSome of the data elements for this information flow are not fully defined.(None)Moorhead PW Operations Center=>work zone information=>MSP DL District
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Fargo PW Operations Center=>work zone information=>NDDOT TOC
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Fargo PW Operations Center=>work zone information=>MATBus
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Fargo PW Operations Center=>work zone information=>Fargo TOC
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Moorhead PW Operations Center=>work zone information=>MnDOT D4 TOC
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)FM Maintenance and Construction Management=>work zone information=>FM Information Service Providers
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)FM Maintenance and Construction Management=>work zone information=>FM Traffic Operations
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)FM Maintenance and Construction Management=>work zone information=>FM Emergency Management
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)FM Maintenance and Construction Management=>work zone information=>Media
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)FM Maintenance and Construction Management=>work zone information=>MATBus
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)West Fargo PW Operations center=>work zone information=>MATBus
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Fargo PW Operations Center=>current infrastructure restrictions=>MATBus
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Moorhead PW Operations Center=>work zone information=>MSP DL District
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Moorhead PW Operations Center=>work zone information=>Media
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Moorhead PW Operations Center=>work zone information=>RRRDC
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Moorhead PW Operations Center=>work zone information=>MATBus
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Moorhead PW Operations Center=>current infrastructure restrictions=>MATBus
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Moorhead PW Operations Center=>work zone information=>Fargo TOC
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Fargo PW Operations Center=>work zone information=>MSP DL District
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Fargo PW Operations Center=>work zone information=>MnDOT D4 TOC
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Fargo PW Operations Center=>work zone information=>Media
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)Fargo PW Operations Center=>work zone information=>RRRDC
Overlap of standardsMediumMultiple standards have been developed to address this information and it is unclear which standard should be used to address this specific information flow.(None)West Fargo PW Operations center=>current infrastructure restrictions=>MATBus
Performance not fully defined (medium)MediumThe performance rules are not fully defined for this information flow.(None)(All)
Secure data access not providedMediumThe solution does not define rules on how the application entity authenticates requests to accept or provide data.(None)(All)
Not a standard (minor)LowThe document is publicly available and widely used but it is not currently a formal standard.(None)(All)

Supports Interfaces

SourceDestinationFlow
Fargo PW Operations CenterFargo TOCwork zone information
Fargo PW Operations CenterMATBuscurrent infrastructure restrictions
Fargo PW Operations CenterMATBuswork zone information
Fargo PW Operations CenterMediawork zone information
Fargo PW Operations CenterMnDOT D4 TOCwork zone information
Fargo PW Operations CenterMoorhead PW Operations Centerwork zone information
Fargo PW Operations CenterMSP DL Districtwork zone information
Fargo PW Operations CenterNDDOT TOCwork zone information
Fargo PW Operations CenterRRRDCwork zone information
FM Maintenance and Construction ManagementFM Emergency Managementwork zone information
FM Maintenance and Construction ManagementFM Information Service Providerswork zone information
FM Maintenance and Construction ManagementFM Traffic Operationswork zone information
FM Maintenance and Construction ManagementMATBuswork zone information
FM Maintenance and Construction ManagementMediawork zone information
Moorhead PW Operations CenterFargo PW Operations Centerwork zone information
Moorhead PW Operations CenterFargo TOCwork zone information
Moorhead PW Operations CenterMATBuscurrent infrastructure restrictions
Moorhead PW Operations CenterMATBuswork zone information
Moorhead PW Operations CenterMediawork zone information
Moorhead PW Operations CenterMnDOT D4 TOCwork zone information
Moorhead PW Operations CenterMSP DL Districtwork zone information
Moorhead PW Operations CenterRRRDCwork zone information
West Fargo PW Operations centerMATBuscurrent infrastructure restrictions
West Fargo PW Operations centerMATBuswork zone information